Polycom SoundStructure C16 Design Manual page 662

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 146
ir_chan_id
Argument
Argument value
Channel Type
Virtual Channel
Value Type
Integer
Read/Write Mode
Read/Write
Phys Chans
Infrared Remote Input
Virt Chans
Control
System Limits
Minimum: 0, Maximum: 15
Default
3
User limits
No
Supported
Event Source
No
Description
This parameter sets the channel ID that the specified IR input will respond to.
Polycom HDX IR remotes can be configured to use different channel IDs so
that multiple remotes can be used in the same room to control different equip-
ment without interfering with each other. By default, the HDX IR remote used
channel ID 3. This can be changed by following the instructions in the HDX
Administrator's Guide.
RS-232
ser_baud
Argument
Argument value
Channel Type
Device-Specific System
Value Type
List
Read/Write Mode
Read/Write
9600 : 9600 bits per second (default)
19200 : 19200 bits per second
Values
38400 : 38400 bits per second
57600 : 57600 bits per second
115200 : 115200 bits per second
Event Source
No
Description
This parameter sets the baud rate for the RS-232 port. Hardware flow control
should be enabled for baud rates over 9600 bps (see the ser_flow parameter).
Set IR Remote Channel ID
Baud Rate

Hide quick links: