Control Port Parameters - Polycom SoundStructure C16 Design Manual

Hide thumbs Also See for SoundStructure C16:
Table of Contents

Advertisement

Control Port Parameters

clink_call_active
Argument
Argument value
Channel Type
Device-Specific System
Value Type
Boolean
Read/Write Mode
Read-Only
Event Source
Yes
Description
This parameter gets the call active status of an HDX. This is true whenever the
HDX has an active video or PSTN call. A status message is generated when-
ever the call active status is changed by an HDX.
clink_local_call_active
Argument
Argument value
Channel Type
Device-Specific System
Value Type
Integer
Read/Write Mode
Read/Write
System Limits
Minimum: 0, Maximum: 32
Default
0
User Limits
No
Supported
Event Source
Yes
Description
This parameter gets and sets the call active status that the device broadcasts to
any connected HDX and HDX Microphone Arrays. This primarily controls the
state of the green LED on the HDX Microphone Arrays. Whenever this param-
eter is a value greater than 0, the call active status sent to the HDX and HDX
Microphone Arrays is set to true. This is implemented as an integer command
so that when a call of interest goes active, it can be incremented. When the call
goes inactive, this parameter can be decremented. This provides a count of all
active calls in the system.
Command Protocol Reference Guide
Clink2 Call Active Status
Clink2 Local Call Active Status
A - 141

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents