• To clear the entry, press the [CLR] button.
4
Press the [ENTER] button.
This confirms the entry, and the selected region name and the set transition
rate appear in the numeric keypad control block display.
The transition control block display of the same bank (M/E or PGM/PST)
also shows the setting.
To enter a difference from the current value
After pressing the [ / ] button, enter the difference and press the [TRIM]
button.
To change the sign (+ or ), press the [ / ] button.
Setting the transition rate by a menu operation
Use the following procedure.
1
In the M/E or PGM/PST menu, select first VF7 'Misc,' then HF1
'Transition.'
The Transition menu appears.
2
Select any transition type in the <Transition Type> group.
3
Turn knob 1 to set the transition rate.
Knob
1

Pattern Limit

There are two ways of setting a pattern limit: either by operating the fader lever
to save the fader position, or by using the Wipe menu or DME Wipe menu to
access the Edge/Direction menu for the M/E or PGM/PST bank.
For an overview of the pattern limits, see page 34.
Notes
• A pattern limit only applies when a wipe or DME wipe is selected as the
transition type.
• A pattern limit cannot be applied to an independent key transition (see page
197).
Parameter
Adjustment
Transition Rate
Transition Rate
Setting values
0 to 999 (frame count)