Blink Function

With the blink function, you can obtain the following effects.
Key blink: The key is alternately inserted and deleted at regular intervals. You
Edge blink: The key fill and key edge fill signals are interchanged at regular
Using the blink function
For example, to make the required settings for key 1 on the M/E-1 bank, use
the following procedure.
1
2
3
222
Key Setting Operations Using Menus
In the <DME Select> group, select the DME channel (DME1 to DME8) to
be used.
The colors with which [DME1] to [DME8] are lit show the key assignment
status.
Lit green: The DME currently being monitored
Lit amber: DME assigned to KEY
Off: Unassigned DME
In the DVS-9000 system, the [DME5] to [DME8] buttons are disabled.
Press [Monitor Set].
This assigns the selected DME output to DME MON V and DME MON K.
can set the period of blinking, and the proportion of each cycle for which
the key is inserted.
intervals. You can set the period of blinking, and the proportion of each
cycle for which the original state holds.
In the M/E-1>Key1 menu, select HF6 'Transition.'
The Transition menu appears.
In the <Blink> group, select [Key Blink] or [Edge Blink] to set it on.
Set the blink parameters.
• When key blink is selected
Knob
Parameter
Adjustment
1
Blink Rate
Length of blink cycle
2
Duty
Proportion of cycle for which key
inserted
Setting values
1 to 100
0.00 to 100.00