8 Fit the exhaust manifold; use new gaskets (C1) without jointing compound. The metal gaskets can be fitted
either way around. Tighten the nuts to 22 Nm (16 lbf ft) 2,2 kgf m.
9 Fit the turbocharger if necessary, see Operation 9-2.
10 Fit the induction manifold; use a new joint (D1) without jointing compound. Tighten the setscrews to 22 Nm
(16 lbf ft) 2,2 kgf m.
11 Fit the electrical connection to the coolant temperature sender unit.
C
12 Fill the cooling system, see Operation 12-3. If the thermostat is fitted in the horizontal position (E), air must
be removed from the system. To do this; release the vent screw (E1) until it just tightens. When the coolant is
free from air, close and tighten the vent screw.
13 Connect the air filter.
14 Connect the battery.
15 Eliminate air from the fuel system, see Operation 11-19 for Delphi fuel injection pumps or Operation 11-22
for Stanadyne fuel injection pumps.
16 Start the engine and run it at low speed. Check that oil flows from the holes in the rocker levers. If the oil
flow is correct, fit the rocker cover, see Operation 3-1.
Caution: Do not tighten the cylinder head fasteners again with the engine hot or after a limited period in
service.