900 Series
7 Fit the oil supply pipe to the bearing housing and tighten the union connection. On the lower section of the
oil supply pipe (B1), ensure that dirt does not enter the oil filter head/adaptor plate or the union adaptor. Clean
the threads of the union nut and apply a thread sealant to the union adaptor (B3). Use a spanner to hold the
adaptor and tighten the union nut (B2).
8 Fit the air cleaner hose to the compressor inlet.
9 Fit the crossover pipe (C2) to the compressor outlet and tighten the clips (C1).
7
6
5
B
10 Remove the container from under the oil drain outlet. Fit the oil drain pipe to the oil drain outlet at the bottom
of the bearing housing and tighten the union nut (D3). Put the oil container under the oil drain pipe.
11 Operate the stop control or, where fitted, disconnect the electrical stop control. Operate the starter motor
until there is a flow of lubricating oil from the oil drain pipe of the turbocharger. Where fitted, connect the
electrical stop control.
12 Push the hose (B6) on to the sump elbow (B5) and tighten the clips (B4).
13 Remove the container and discard the lubricating oil in a safe place in accordance with local regulations.
D
Workshop Manual, TPD 1345E, issue 3
This document has been printed from SPI². Not for Resale
2
1
3
4
C0139A
1
2
6 6
5
3
6 6
4
C0140B
1
C
9
2
C0141A
131