11 Data Back-Up
11.4 Data back-up via PG/PC
Operating
procedure
(data back-up)
11-230
1. Connect the PG/PC
2. In the "Services" area of the HMI,
3. select "RS-232 PG/PC" interface (vertical soft key).
4. Select "Settings" and check or enter the parameter settings of the RS-232
interface (default setting).
Device type:
Baud rate:
Parity:
Data bits:
Stop bits:
XON character:
XOFF character:
End of text character: 1AH(ex)
Format:
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
RTS/CTS
9600 Baud
no
8
1
11H(ex)
13H(ex)
– Punched tape format unchecked
for standard system start-up or for backing up
drive data by area (boot files)
– Punched tape format checked for backing up
all other data by area.