5. Read in the option data and carry out an NCK reset.
6. Load the machine data file and press "NCK-Reset". If any messages are
7. If global user data is activated, the "N_INITIAL_INI" file (Table 11-1) should
8. Read in archive file for global user data (MAC.DEF and GUD.DEF).
9. Reload the backed up "N_INITIAL_INI" file to activate the global user data.
10. Then load the other areas.
11. The PLC area must be loaded last after a PLC general reset.
Note
S
S
Transmission
If the transmission is canceled with errors, check the following:
errors
S
S
S
S
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
then received about reconfiguring the memory or rescaling machine data,
the machine data file must be read in again and the control reset. It is gene-
rally necessary to repeat this two or three times.
be read. It is read out through selection of the setting "All data" as for area-
specific archiving.
When you are loading drive data, deselect the tape format as well as all
special functions on the right of the display of interface settings.
Do not actuate soft key "Back up boot file" in the drive data menu until you
have reset the control once after loading the drive archive data.
Check/correct the interface settings after display of a message regarding
memory reconfiguration.
If the password set to the correct protection level.
Are the interface parameters (V24-PG/PC) correct.
When reading in LEC data, first
set MD 32700 ENC_COMP_ENABLE to 0.
Set MD11220 INI_FILE_MODE to 1 or 2 (see the "Response to cancellation
when reading in machine data" section below).
11 Data Back-Up