Siemens SINUMERIK 840D Simodrive 611 digital Startup Manual page 222

Table of Contents

Advertisement

10 Drive Optimization
10.9 Automatic controller settings ( HMI Advanced only)
3
3
Do you want to back up the
boot file for drive X and
display the modified
controller data?
SK "Yes"
Boot file is
saved
Start
measurement of
speed controller?
SK "OK"
Prompt to press NC-Start
Warning:
Pressing NC-Start causes the axis
to perform a traversing motion.
End
10-222
SK "No"
Enter the
measuring
SK "Parameter"
parameters
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
Boot file is not
saved
SK "Abort"
(discard
changes)
SK "OK"
(accept
values)
© Siemens AG 2006 All Rights Reserved
03/2006

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810d simodrive 611 digital

Table of Contents