Determination of
the reset time
Fig. 10-26 Determination of the reset time
Frequency at or above which a filter can be used:
Current filters are not used below this frequency.
Min. amplitude:
This figure may not be exceeded between the minimum frequency and the
lower frequency limit (lower adaptation limit).
Max. amplitude:
This figure may not be exceeded at or above the upper frequency limit.
The two frequency entries can be used to modify the adaptation range.
Speed control loop
measurement
Fig. 10-27 Speed control loop measurement
Amplitude:
Enter the loading speed in mm/min (should be max. 50% of the offset).
Bandwidth:
Any bandwidth can be selected from the default values in order to check the
automatic controller setting.