11 Data Back-Up
11.1 General
Required
accessories
Structure of the
file names
Examples
11-228
You will need the following accessories in order to back up the data:
S
PCIN data transmission program for PG/PC
S
V24 cable 6FX2002-1AA01-0BF0
Reference material: /Z/ Catalog NC Z (Accessories)
S
PG or PC (DOS)
_N_
Area
S
The area specifies which data are to be backed up or retrieved (general,
channel-specific or axis-specific).
S
The unit defines the channel, the axis or the TOA area. The unit is omitted if
the entire area has been selected.
S
The type determines the type of data. For a data back-up, the file name are
generated and output automatically.
Areas
NC
general NC-specific data
CH
channel-specific data (unit corresponds to the channel number)
AX
axis-specific data (unit corresponds to the number of the
machine axis)
TO
tool data
COMPLETE
all the data in an area
INITIAL
data for all areas (_N_INITIAL_INI)
Types
TEA
machine data
SEA
setting data
OPT
option data
TOA
tool data
UFR
user input frames: variable NPV, rotations, etc.
EEC
measuring system error offset
CEC sag/angularity compensation
QEC quadrant error offset
PRO protection area
RPA
R parameters
GUD Global user data
INI
general initialization program (all the data for the active filter system)
_N_COMPLETE_TEA
archiving of all machine data
_N_AX_TEA
archiving of all axis machine data
_N_CH1_TEA
archiving of the machine data for channel 1
_N_CH1_GUD
archiving of the machine data for channel 1
_N_INITIAL_INI
archiving of all the data in the active file system