Siemens SINUMERIK 840D Simodrive 611 digital Startup Manual page 181

Table of Contents

Advertisement

03/2006
Canceling
The following event cause active measuring functions to be canceled:
measuring
functions
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
– Hardware limit switch reached
– Traversing range limits exceeded
– Emergency stop
– Reset (mode group, channel)
– NC stop
– Removal of controller enable
– Removal of drive enable
– Removal of travel enable
– Park function is selected (in position-controlled mode)
– Feed override 0%
– Spindle override 50%
– Change of operating mode (JOG) or JOG operating mode not selected
– Pressing the Travel buttons
– Turning the handwheel
– Alarms that cause the axes to stop
10 Drive Optimization
10.2 Measuring functions
10-181
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810d simodrive 611 digital

Table of Contents