03/2006
Temperature
This connection variant has proved to extremely immune to interference and
sensor coupling
should always be employed.
lead (= dongle)
If an incremental measuring system is used, the drive is synchronized coarsely
using the rotor position identification routine.
–X411
SIMODRIVE
611 D
Drive A
U2 V2 W2 PE
Fig. 6-39
Temperature sensor coupling lead (recommended standard connection)
© Siemens AG 2006 All Rights Reserved
SINUMERIK 840D/810D Start-Up Guide (IADC) – 03/2006 Edition
6.10 Linear motors (1FN1 and 1FN3 motors)
Encoder cable
6FX2001-2CG00-xxxx (increment)
6FX2002-2CH00-xxxx (absolute)
Temperature sensor coupling lead (dongle)
6FX2002-1AA14-xxxx
Power cable
6 Programming the control
Linear scale
Primary section
6-149