Skip Command Prefix

This parameter determines if the printer will print any data before a
PGL command is received.
Enable. The printer ignores all data on the current line before
an IGP command.
Disable. The printer will print all data on the current line before
an IGP command.
Power On IGP/PGL
You can set the IGP feature so that it is enabled or disabled when
the printer is powered on.
Enable. The PGL is enabled when the printer is powered on.
(The PGL feature is initialized in the Normal mode.)
Disable. The PGL is disabled when the printer is powered on.
(The PGL feature is initialized to the Quiet mode.)

Extended Execute Copy

Disable. Dynamic data and overlay data are not allowed if the
optional Form Count parameter (number of forms to print) is
specified as part of the Execute command. (This setting is IGP-
100 compatible.)
Enable. Only dynamic data is allowed within a form in which
the Form Count parameter is specified in the Execute
command. In this case, the exact same form (with identical
dynamic data, etc.) is printed for whatever the Form Count is.
However, incremental data is not incremented since the page
that is printing is exactly the same. Also, each form is printed
on a separate page.