Mantenimiento Periféricos Informáticos SL C/Canteras, 15 28860 Paracuellos de Jarama Tel: 00 34 917481604 WEB: https://mpi.com.es
Define LF Code (Line Feed)
This parameter forces the printer to insert an automatic Carriage
Return code into the data stream whenever a Line Feed code
occurs. This can be used in most installations, but it is required if
the host computer does not send Carriage Returns to the printer.
•
LF = LF. Does not perform an automatic carriage return. The
next print position will be the current print position of the next
line.
•
LF = CR + LF. Performs an automatic carriage return. The next
print position will be print position 1 of the next line.
Autowrap
This parameter determines if text will wrap to the next line when the
line of text exceeds the right margin.
•
Disable. Truncates the text beyond the right margin until a CR
or CR + LF is received.
•
Enable. Automatically inserts a CR + LF after a full print line.
Select SFCC
You can specify which hex code (1-255) will be used as the Special
Function Control Code (SFCC). The factory default setting is 126.
The SFCC denotes that the following data is a PGL command.
PI Slew Range
You can specify how many lines the paper will feed.
•
15. A paper slew of 1-15 will move 1-15 lines. A paper slew of 0
will move 1 line.
•
16. A paper slew of 0-15 will move 1-16 lines.
Submenu