Select A Site
Select a printer site that meets all of the following requirements:
Permits complete opening of the printer cover and doors.
For cabinet models, allows at least three feet of clearance
behind the printer. (This permits air to circulate freely around
the printer and provides access to the paper stacking area.)
Has a standard power outlet that supplies 88-135 Volts AC or
178-270 Volts AC power, at 47 to 63 Hz.
Is relatively dust-free.
Has a temperature range of 10° C to 40° C (50° F to 104° F),
and a relative humidity from 15% to 90% non-condensing.
Is located within the maximum allowable cable length to the
host computer. This distance depends on the type of interface
you plan to use, as shown in Table 2.
Table 2. Maximum Interface Connection Cable Length
Interface Type
Centronics Parallel
Dataproducts Parallel
IEEE 1284 Parallel
Serial RS-232
Serial RS-422
Dataproducts Long Line
Coax
Twinax
Twinax (Shielded cable)
Twisted Pair / Type 3
Ethernet 10Base-T
Ethernet 10Base2
Ethernet 10/100Base-T
18
Maximum Cable Length
5 meters (15 feet)
12 meters (40 feet)
10 meters (32 feet)
15 meters (50 feet)
1220 meters (4000 feet)
150 meters (492 feet)
1500 meters (4920 feet)
1500 meters (4920 feet)
1500 meters (4920 feet)
300 meters (985 feet)
100 meters (328 feet)
185 meters (607 feet)
100 meters (328 feet)