Chapter 4
LinePrinter Plus Emulation

P-Series XQ Emulation

Printer
Protocol
(from page 147)
P-Series
XQ
Control Code
Define CR
06
Code
6.0 LPI
CR = CR*
8.0 LPI*
CR = CR + LF
10.3 LPI
HS Print
VFU Select
char 02 STX*
EVFU*
char 03 ETX
DVFU
char 09 HT
CVFU
Disable
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK).
You can select an alternate line spacing of 6, 8 or 10.3 LPI.
Define CR Code
This option controls the action of the printer when it receives a
Carriage Return code (hex 0D) from the host computer. If this
feature is enabled, each time the printer receives a Carriage
Return, it inserts an additional Line Feed code (hex 0A) into the
data stream. Do not use this feature if the host computer sends
Line Feeds to the printer.
CR = CR. Does not insert an extra Line Feed after each
Carriage Return.
160
Define LF
Auto LF
Code
Disable*
LF = CR + LF*
Enable
LF = LF
Upr. Case
Slew
Select
Relative
Disable*
1-16 Lines*
Enable
1-15 Lines
* = Factory Default
Compressed
Elong./Alt.
Print
Font
char 01 SOH*
Elng=BS Font=SO*
char 03 ETX
Elng=SO Font=BS
char 09 HT

Hide quick links: