Table 8. LCD Message Troubleshooting Table (continued)
EXHAUST FAN FLT
(Cabinet model only)
FIRMWARE
ERROR*
FM HEADER
ERROR*
FRAMING ERROR
GRF CHK ERROR
PRESS STOP
Mantenimiento Periféricos Informáticos SL C/Canteras, 15 28860 Paracuellos de Jarama Tel: 00 34 917481604 WEB: https://mpi.com.es
Yes
Sensors cannot
detect current in fan
circuit.
No
Application
software tried to
perform an illegal
printer function or
damaged memory
detected on board.
No
Applications
software has
violated header
parameters.
Yes
Serial framing error
(serial interface).
Yes
Printer has received
a non-printable
character.
Fault Messages
Power off the printer and
remove the paper path
(see Maintenance
Manual). Check that the
fan cable connector is
connected. Check for
obstruction of vents and
fan airway, and remove
any obstructions. Check
for items beneath the
printer blocking cabinet
vents. Power back on
the printer. If this
message recurs, contact
your authorized service
1
representative.
Contact your authorized
1
service representative.
Contact your system
administrator.
Check your serial host
interface parameter
settings; if necessary,
adjust them so that they
match the settings of the
attached host.
Press CLEAR and then
ON LINE.