Error Messages
"Slow or Missing Clock"
"Slow or Missing Clock"
This error might occur if the target system is not running properly.
Ensure that the target system is on and operating properly.
Check your State clock configuration. The proper clocking scheme
should be listed in your preprocessor interface User's Guide.
If the error message persists, check that the logic analyzer pods are
connected to the proper connectors. See the User's Guide for your
preprocessor interface to determine the proper connections.
"Waiting for Trigger"
If a trigger pattern is specified, this message indicates that the specified
trigger pattern has not occurred. Verify that the triggering pattern is
correctly set.
When analyzing microprocessors that fetch only from long-word aligned
addresses, if the trigger condition is set to look for an opcode fetch at an
address not corresponding to a long-word boundary, the trigger will
never be found.
10–11