To Assign Terms To An Analyzer - HP 1660CS-Series User Manual

Logic analyzers
Table of Contents

Advertisement

Using the Trigger Menu

To assign terms to an analyzer

To assign terms to an analyzer
When you turn the logic analyzer on, Analyzer 1 is named Machine 1 and
Analyzer 2 is off. Trigger terms can only be used by one analyzer at a time,
so all the terms are assigned to Analyzer 1. If you plan to use both analyzers
in your measurement, you need to assign some of the terms to Analyzer 2.
Go to the Trigger Machine 1 menu.
1
If you have renamed Machine 1 in the Analyzer Configuration menu, the
name you changed it to will appear in the menu instead of Machine 1.
Select a term.
2
The terms are the fields below the roll field "Terms". See the figure below.
Terms
Select Assign from the list that appears.
3
The Resource Term Assignment menu appears. It is divided into two
sections, one for each analyzer. All the terms are listed.
To change a term assignment, select the term field.
4
The term fields toggle from one section to the other. You can get all your
terms assigned at once, or just change a few to meet immediate needs.
To exit the term assignment menu, select Done.
5