HP 1660CS-Series User Manual page 265

Logic analyzers
Table of Contents

Advertisement

The Trigger Sequence
Trigger sequence specification
Sequence-else specification The sequence-else branch, sometimes
called the "else if" branch or secondary branch, may branch to any other
state, including the current state, a previous state, or a later state. The
sequence-else specification looks like the following:
Else on "<TERM>" go to level <sequence level>
If the Sequence-Else specification is satisfied before the sequence-advance
specification, the trigger sequence goes to <sequence level>.
The last state may only have a sequence-else branch specification, which may
branch to the same state or a prior state.
Storage specification In each state, a storage specification determines
the data stored by the analyzer while it is searching for the
sequence-advance, sequence-else, and trigger specifications. Storage
specifications are defined using the same pattern, range, and timer
resources available for defining branching specifications.
While storing "anystate", "no state", or "<TERM>"
Note that if you specify "no state," the analyzer still stores sequence-advance
terms and trigger terms unless you also set Branches Taken Not Stored in
Acquisition Control in the Analyzer Trigger menu.
Trigger on specification If there are branch and storage specifications
for each sequence level, what does the trigger term mean? The trigger
term is a special sequence-advance specification in that, when found, it
locks the contents of analyzer acquisition memory. The trigger can be
positioned at the beginning, middle, or end of acquisition memory.
The trigger specification can look like the following:
TRIGGER on "<TERM>" <OCCURS> times
TRIGGER on "<TERM>" <TIME PERIOD>
If the trigger term is found <OCCURS> times, or if the trigger term remains
stable for <TIME PERIOD>, the trigger is captured in memory. Then the
analyzer advances to the next sequence level. If you want to capture activity
after the trigger is captured, define an additional sequence level and specify
the desired storage qualification for post-trigger activity (for example, store
anystate).
9-14

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

1662cs1663cs1660cs1661cs

Table of Contents