Configure process measurement
Derived
Variable
Description
Mass
The percent mass of
Concentration
solute or of material in
(Specific Gravity)
suspension in the total
solution, derived from
specific gravity
Volume
The percent volume of
Concentration
solute or of material in
(Density)
suspension in the total
solution, derived from
reference density
Volume
The percent volume of
Concentration
solute or of material in
(Specific Gravity)
suspension in the total
solution, derived from
specific gravity
Concentration
The mass, volume,
(Density)
weight, or number of
moles of solute or of
material in suspension
in proportion to the to-
tal solution, derived
from reference density
Concentration
The mass, volume,
(Specific Gravity)
weight, or number of
moles of solute or of
material in suspension
in proportion to the to-
tal solution, derived
from specific gravity
4.9
Set up concentration measurement using a
basic FF host
This section guides you through most of the tasks related to setting up and implementing
the concentration measurement application.
Restriction
This section does not cover building a concentration matrix. See Micro Motion Enhanced Density
Application: Theory, Configuration, and Use for detailed information on building a matrix.
48
Calculated process variables
Density at
reference
Standard
tempera-
volume
Specific
ture
flow rate
gravity
Micro Motion Model 2700 Transmitters with FOUNDATION Fieldbus
Concen-
Net mass
tration
flow rate
Net
volume
flow rate

Hide quick links: