4.5

Configure density measurement

The density measurement parameters control how density is measured and reported.
4.5.1

Configure Density Measurement Unit

Display
ProLink III
Field Communicator Configure > Manual Setup > Measurements > Density > Density Unit
Fieldbus host
Overview
Density Measurement Unit controls the measurement units that will be used in density
calculations and reporting.
Procedure
Set Density Measurement Unit to the option you want to use.
The default setting for Density Measurement Unit is g/cm3 (grams per cubic centimeter).
Options for Density Measurement Unit
The transmitter provides a standard set of measurement units for Density Measurement
Unit. Different communications tools may use different labels.
Unit description
(1)
Specific gravity
Grams per cubic centimeter
Grams per liter
Grams per milliliter
Kilograms per liter
Kilograms per cubic meter
Pounds per U.S. gallon
Pounds per cubic foot
Pounds per cubic inch
Short ton per cubic yard
Configuration and Use Manual
OFF-LINE MAINT > OFF-LINE CONFG > UNITS > DENS
Device Tools > Configuration > Process Measurement > Density
Measurement TB > DENSITY_UNITS (OD Index 23)
Display
ProLink III
SGU
SGU
G/CM3
g/cm3
G/L
g/l
G/mL
g/ml
KG/L
kg/l
KG/M3
kg/m3
LB/GAL
lbs/Usgal
LB/CUF
lbs/ft3
LB/CUI
lbs/in3
ST/CUY
sT/yd3
Configure process measurement
Label
Field Communicator
SGU
g/cm3
g/L
g/ml
kg/L
kg/m3
lb/gal
lb/ft3
lb/in3
STon/yd3
33