• However, if an event that requires successive rebooting occurs, the machine will display the SC
code without rebooting and perform logging count. If you print the service summary, the events that
required successive rebooting will be displayed with asterisks.
• Automatic rebooting can be set to on/off in SP5-875-001 (Default: on).

Service Call Code Tables

SC
Pattern
The maintenance motor is not in the home position.
20000
D
Turn the main power switch off and then back on.
SC
Pattern
Failure to form negative pressure in the maintenance unit (while assessing the
negative pressure in the tank)
20200
D
Turn the main power switch off and then back on.
SC
Pattern
Failure to form negative pressure in the maintenance unit (air leak) (Tank 1
error)
20211
D
SC
Pattern
Failure to form negative pressure in the maintenance unit (air leak) (Tank 2
error)
20212
D
Turn the main power switch off and then back on.
Error Name / Detection Criteria / Major Cause / Solution
Error Name / Detection Criteria / Major Cause / Solution
Error Name / Detection Criteria / Major Cause / Solution
Error Name / Detection Criteria / Major Cause / Solution
Error Codes