3.Use a damp cloth to clean the surface of the friction pad [A].
Horizontal Encoder Strip Cleaning
Clean the horizontal encoder strip if the following conditions occur:
• Vertical white lines on an image
• Double image
• Broken vertical lines
• JAM 14
Sample image of horizontal white lines
Cleaning procedure
Preparation
• Duplex unit (
p.48)
• Left cover (
p.56)
Cleaning
151