5 UTILITY PACKAGE (GX Configurator-AD)
5 - 20
[Explanation of items]
(1) Items
Setting item
Current value
Setting value
(2) Command buttons
Current value display
Make text file
Start monitor /
Stop monitor
Execute test
Close
(3) Example of the operation of selection test
The following is an example of the operation of selection test where sampling
processing of CH1 is changed to a 10 times averaging processing.
(a) On the monitor/test window, click the CH1 Operating condition setting request
button.
(b) Change the Setting value field of CH
"Average number of times".
(c) Click and select the Setting value field of CH
number of times/Move average/Time constant settings.
(d) After entering the average number of times, press the Enter key.
At this point, the value is not yet written to the A/D converter module.
(e) Hold down the Ctrl key and select the Setting value field where the value
has been entered by the operation performed in (b) to (d). Multiple items can
also be selected by performing mouse drag operation.
(f) Click the Execute test button to execute write operation for the set data.
Once writing has been completed, the value that was written will be
displayed in the current value field.
: Displays I/O signals and buffer memory names.
: Monitors the I/O signal states and present buffer memory
values.
: Select or enter the data to be written during test operation.
Displays the current value of the item selected. (This is
used to check the text that cannot be displayed in the
current value field. However, in this utility package, all
items can be displayed in the display fields).
Creates a file containing the screen data in text file
format.
Selects whether or not to monitor current values.
Performs a test on the selected items. To select more
than one item, select them while holding down the
Ctrl key.
Closes the screen that is currently open and returns to
the previous screen.
MELSEC-Q
Averaging process specification to
Average time/Average
5 - 20