Configure The Optical Sfp Modules Gigabit Ethernet - Ericsson EDA 2530 Commissioning Instructions

Commissioning procedure for cable and wireless access
Table of Contents

Advertisement

7.1

Configure The Optical SFP Modules Gigabit Ethernet

a.
b.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
Note1: If the EDA 2530 is to be the "Parent" node & subtend an existing
EDA 2510 node, then the backhaul SFP required for Port 1 (SU57AE
1310nm) will be recovered from the EDA 2510 SFP Port 3 when the two
nodes are migrated during a PEW, at a later date.
Note2: CP Port SFP1 will be utilised as the Network interface to backhaul to
the IP Network.
Note3: CP Port SFP2 (when fitted) will be used by the "Parent" to subtend
the "Child#1", an EDA 2510 node.
Note4: CP Port SFP3 (when fitted) will be used by the "Parent" to subtend
the "Child#2", an EDA 2530 node.
Note5: CP Port SFP4 (when fitted) will be used by the "Parent" to subtend
the "Child#3", an EDA 2530 node.
Note6: SFP Modules approved by Marconi are 'Moni Tagged' and will be
configured automatically when inserted.
On the Common Part card:- (Check details with the site's SID document)
Insert SFP1 module (if available) into Port 1 (SU57AE - 1310nm).
Insert SFP2 module (if supplied) into Port 2 (SU57AD - 850nm).
Insert SFP3 module (if supplied) into Port 3 (SU57AD - 850nm).
Insert SFP4 module (if supplied) into Port 4 (SU57AD - 850nm).
Right click on the CP Card and select SFP Provisioning from the sub
menu. The "CP-IP SFP/Port Provisioning" screen will appear.
EDA 2530 Commissioning Procedure for Cable and Wireless Access
© Ericsson AB 2010
Commercial in confidence
69 (200)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents