Configure Pots Card(S); Pots Card Configuration Files; Step 1: Lct 07.02.05 - Known Issue With Java Version 1.6; Step 2: Add Pots Card(S) Interfaces To Static Vlans - Ericsson EDA 2530 Commissioning Instructions

Commissioning procedure for cable and wireless access
Table of Contents

Advertisement

7.17

Configure POTS Card(s)

7.17.1

POTS Card Configuration Files

In order to commission the POTS cards a set of generic POTS configuration files will
be required for each site.
commissioning and will be supplied to the site commissioning engineer. The site
commissioning engineer will load these files and then modify the data to the site
configuration requirements. i.e. IP Addresses, Node DLE ID, POTS card IP
Addresses and quantity of POTS cards installed.
Create a folder "POTS Configuration Files" on your PC. Store the generic POTS
configuration files in this folder.
File Name
Generic H248 Terminations Configuration – Slot x
Generic H248 VGW Configuration Slots 3 to 21
Generic POTS RTP Profiles
POTS ToIP Profile (File no longer required)
National Mapping file
7.17.2
Step 1: LCT 07.02.05 – Known Issue with Java Version 1.6
LCT 07.02.05 has a known issue with the National Mapping Tool and setting up the
repository location when Java version 1.6 has been installed.
a.
b.
7.17.3

Step 2: Add POTS Card(s) Interfaces to Static VLANs

a.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
To correct this issue the commissioning engineer must remove Java 1.6,
the LCT, & all of the LCT packages, then re-install them again but with Java
version 1.5 before attempting to configure the POTS card(s). Follow
Section 3.5.4 where this process is detailed.
Copy and replace the existing file "setenv80_13.bat" with the latest one
provided, in folder C:\Mv36bLT\Lib\env (you may wish to backup the
existing file before doing so).
Note: If this file is not replaced then when loading the National Mapping
file, the browse button is not available and Columbia will be selected
instead of the United Kingdom.
For all installed POTS cards, an "iLag" interface must be created for each
POTS card against the appropriate VOIP_GWx name for the relevant slot
positions.
EDA 2530 Commissioning Procedure for Cable and Wireless Access
These will be prepared in advance of the site
File Type
.trm
.hvgw
.rtp
.tip
.gz
© Ericsson AB 2010
Commercial in confidence
File Quantity
10 files - 1 per slot for all sites.
1 for all sites for all 10 slots
1 for all sites.
1 for all sites. (Standard)
1 for all sites. (Standard)