Configure Shdsl Line Profiles - Ericsson EDA 2530 Commissioning Instructions

Commissioning procedure for cable and wireless access
Table of Contents

Advertisement

7.15
Note: This section ONLY applies to SHDSL Profiles.
Configure the EDA2530 SHDSL Line Profiles via the LCT.
a.
b.
c.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01

Configure SHDSL Line Profiles

From the LCT main screen select the path Configuration > SHDSL
Profiles and Setup.
Profiles" screen will be displayed:-
Note: If there is an SHDSL card already configured in the EDA2530 then
click the Read Network button to view and check the SHDSL Line Profiles.
If the profiles are correct this sub-section is not required. If the profiles are
not correct then perform the rest of this sub-section.
Select File > Open, then navigate to the "SHDSL Line Profiles.lcp" template
file. Then select Open to load this profiles file.
In the "Ne Name" column the template will load the default OOB IP
address of 150.150.150.4, the Node being commissioned is likely to have a
different one allocated to it. The Out Of Band IP Address is determined by
the DLE ID, refer to Section 5.5. Change the address (if necessary) in this
column for all entries, as follows:-
EDA 2530 Commissioning Procedure for Cable and Wireless Access
Click Conf Profiles button.
© Ericsson AB 2010