c.
d.
e.
f.
g.
h.
i.
j.
9.2.2
Test 32 x SHDSL Cards
Test all 32 x SHDSL cards (02HAT00274AAE).
The 32 x SHDSL lines are grouped as 1 to 4, 5 to 8, 9 to 12, 13 to 16, 17 to 20, 21
to 24, 25 to 28 and 29 to 32.
All SHDSL Lines should be tested from each group of four lines. This will ensure
that each line IC is tested.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
When the SHDSL x 32 Lines window appears click on the SHDSL Line to
be enabled or disabled then left click on the Configure button.
Click on the Status tab.
If the Disable button is greyed out, this indicates that the line is disabled.
Click on the Enable button to enable the line.
The Enable button should now be greyed out and the Disable button should
be available.
If the Enable button is greyed out, this indicates that the line is enabled.
Click on the Disable button to disable the line.
The Disable button should now be greyed out and the Enable button should
be available.
EDA 2530 Commissioning Procedure for Cable and Wireless Access
© Ericsson AB 2010
Commercial in confidence
168 (200)