Software Inventory Check

Check the Software Inventory on each 64 x ADSL2+ card, 64 x POTS/VoIP card
and 32 x SHDSL card.
software release for the shelf. There is one acceptable release.
This table shows the Software R4.21 GA EC2 for the EDA 2530 cards.
Card Type
CP 2530-IP
64 x ADSL2+
64 x POTS/VoIP
32 x SHDSL
a.
b.
c.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
From the resulting window change the IP Address to a value in line with the
above table, also refer to the Network Planner's guide for the site. Leave
the IP Network Mask address at 255.255.255.0, and select "Apply
Changes" to update the OBM IP address.
From the left-hand side options select "LOG OUT" to log out of the EDA
2500 Element Manager and return to the internet browser.
Close down the Internet Browser.
From the main LCT screen select Maintenance > Equipment reboot.
From the following window click on the "Warm reboot" button, select the
"Reboot" option and "Yes" to continue.
The equipment will log out of the LCT and the CP card will reboot.
Wait around 5 min before attempting to login again, this time using the new
OBM IP address.
The software in the Common Part card identifies the
EDA 2530 Software R4.21 GA EC2
Unit Code
02HAT00103ACY
02HAT00162AAD
02HAT00198AAM CXC 172 4797 R2B
02HAT00274AAE
Logon to the EDA 2530 again.
Right click on the Common Part card in slot 1, select HW/SW Inventory
from the option menu.
In the window displayed, check that the Running Bank (Yes) contains the
correct software code and release. This is an example screen.
EDA 2530 Commissioning Procedure for Cable and Wireless Access
Software Code
CXC 172 4796 R3D
CXC 172 3777 R2B
CXC 172 5103 R1B
© Ericsson AB 2010
Commercial in confidence
Release
Date
R3D02
090529
R2B27
090129
R2B30
090129
R1B18