7

Configure IP and Ethernet Management

The following table gives a list of the site specific information required to commission
the EDA 2530, without this information the commissioning of the node cannot
commence. Most of this information is provided in the CWA "DLE planning"
spreadsheet, produced by CWA DLE Management.
CWA "DLE planning"
Ref.
DSLAMID
S-VLAN
C-VLAN
Mask
AHX IP Addr
BRAS IP Addr
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
EDA 2530 Commissioning Procedure for Cable and Wireless Access
Comissioning
Example / Comments
Procedure/LCT
Ref.
eg EANCN0102 (Norwich North), this is
Node DLE ID
site specific.
Specified in site SID document.
150.150.150.x
OOB IP Address
Where x=4 (default) to 15
Out Of Band IP Address is determined
(Out Of Band)
by the DLE ID, refer to Section 5.5.
21 or 22
SVID
To be specified by CWA.
If parenting EDA2530 to an existing
EDA2510, will use the same value as
used by the EDA2510.
Parent EDA2530
CVID
Child#1 EDA2530
Child#2 EDA2530
Child#3 EDA2530
Where y = 1 to 64 for xDSL ports 1 - 64
Where y = 1 to 32 for SHDSL ports 1 -
32
E.g. 30 or 31
Mask Length
Number of bits of subnet mask.
To be specified by CWA.
In Band Management IP Address.
IBM IP Address
To be specified by CWA.
Route
Gateway
To be specified by CWA.
IP Address
© Ericsson AB 2010
Commercial in confidence
3200 + y
200 + y
1200 + y
2200 + y
67 (200)