64 X Adsl2+ Unit Extraction/Insertion; 32 X Shdsl Unit Extraction/Insertion - Ericsson EDA 2530 Commissioning Instructions

Commissioning procedure for cable and wireless access
Table of Contents

Advertisement

c.
8.2.4

64 x ADSL2+ Unit Extraction/Insertion

a.
b.
c.
8.2.5

32 x SHDSL Unit Extraction/Insertion

a.
b.
c.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
Check the following alarms now clear on the alarm browser:-
"cpHighTemperatureTrap"
"cpEqtSubrackCoolingFanStatusChangedTrap"
"cpCoolingFanFailureTrap"
Extract a 64 port ADSL unit and check that:-
The LCT equipment view displays the extracted unit.
Check the following alarms appear on the alarm browser:-
"cpEqtCardActualChangedTrap"
"cpReplaceableUnitMissingTrap"
Insert the previously extracted unit and check that:-
The inserted unit is displayed correctly and without alarms.
Refresh the Alarm Browser, check the following alarms disappear on the
alarm browser:-
"cpEqtCardActualChangedTrap"
"cpReplaceableUnitMissingTrap"
Repeat steps a. and b. for all other 64 port ADSL2+ units.
Extract a 32 port SHDSL unit and check that:-
The LCT equipment view displays the extracted unit.
Check the following alarms appear on the alarm browser:-
"cpEqtCardActualChangedTrap"
"cpReplaceableUnitMissingTrap"
Insert the previously extracted unit and check that:-
The inserted unit is displayed correctly and without alarms.
Refresh the Alarm Browser, check the following alarms disappear on the
alarm browser:-
"cpEqtCardActualChangedTrap"
"cpReplaceableUnitMissingTrap"
Repeat steps a. and b. for all other 32 port SHDSL units.
EDA 2530 Commissioning Procedure for Cable and Wireless Access
© Ericsson AB 2010
Commercial in confidence
150 (200)