Configure The Default Gateway - Ericsson EDA 2530 Commissioning Instructions

Commissioning procedure for cable and wireless access
Table of Contents

Advertisement

7.10

Configure The Default Gateway

a.
b.
c.
d.
e.
f.
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
From the main LCT screen select the path, Configuration > IP Ethernet
Management > Static Routing Table. The following screen will be
displayed:-
If there is already a filled in entry in the first line, then highlight it and select
"Delete" to remove it.
Highlight the empty first row of the table and click on the "Details >>"
button, the window will be expanded to display "Routing Details".
In the "Route Dest" field enter 0.0.0.0.
In the "Route Mask" field enter 0.0.0.0.
In the "Route Gateway" field enter the IP address supplied by the CWA
planning document. This IP address is known as "BRAS IP Addr", which is
the Inband Management Default Gateway.
Click on "Create" to populate the Static Routing table, as shown below.
Close all windows to return to the main LCT screen.
EDA 2530 Commissioning Procedure for Cable and Wireless Access
© Ericsson AB 2010
Commercial in confidence
100 (200)