Vertical mount contact connector

This FRU contains a vertical mount contact connector. Read the instructions before proceeding.
The vertical mount contact connector uses a back flip locking actuator to lock the ribbon cable into the Zero
Insertion Force (ZIF) connector. The cable is inserted vertically into the connector.
Warning—Potential Damage: When opening or closing this type of actuator, gently lift the center of the
actuator using your finger. Do not use a fingernail or screwdriver to open the actuator. This could damage
the ribbon cable. Do not close the actuator from the ends of the actuator.
Removing a cable from the vertical mount contact connector
1
Gently rotate the locking actuator from the center of the actuator to the unlocked position.
2
Slide the cable out of the connector.