3
Rotate the locking actuator to the locked position.

Vertical mount contact connector

This connector uses a back flip locking actuator to lock the ribbon cable into the ZIF connector.
Warning—Potential Damage: When opening or closing this type of actuator, gently lift the center of the
actuator using your finger. Do not use a fingernail or screwdriver to open the actuator to avoid damaging the
ribbon cable. Do not close the actuator from its ends.
Removing the cable
1
Rotate the locking actuator from the center of the actuator to the unlocked position.
2
Remove the cable.
Parts removal