Trigger Input (Lower Trigger Execution) - Omron V600 Series User Manual

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Section 4
Function

Trigger Input (Lower Trigger Execution)

The ID Controller uses trigger inputs to inform the ID Controller when to start processing the Data
Carrier. After receiving a command from the host device, the ID Controller will wait until the rising edge
of the trigger input and then start communications with the Data Carrier. There are two trigger inputs.
TRG/IN1 is used to control read/write event 1 and TRG/IN2 is used to control read/write event 2.
Command
received?
Y
Detected
rising edge of
trigger
input?
Y
Command processed.
Response processed.
For AUTO commands, the ID Controller will start waiting for a Data Carrier to approach after the trigger
input is received. Therefore, read/write processing will not be performed until the trigger input is
received even if a Data Carrier approached the ID Controller.
AUTO command
becomes active.
received.
Wait for trigger input.
(See note.)
Note: Processing will not be performed while waiting for the trigger input even if a Data Carrier
approaches.
RFID System
60
Operation Manual
N
N
Note: Processing will not be aborted even if the status of the trigger
input changes during processing.
Trigger input
Data Carrier
approaches.
Wait for Data Carrier
Wait for Data Carrier
communications.
to approach.
Response sent.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca5d02V600-ca5d01

Table of Contents