Section 5
Communications
AUTO COPY (AP)
For AUTO COPY, the ID Controller waits until a Data Carrier approaches and then Writes data read
from Data Carrier memory by one Read/Write Head to the memory of a Data Carrier in the
communications area of the other Read/Write Head.
The data is always written to the destination Data Carrier on the trigger.
■ 1:1 Communications
Command
Data code
specifica-
Command code
tion
H
A
P
2
1
Data code specification
R/W Head No.
Read area start address
No. of bytes to copy
Copy destination write start
address
Response
Command code
End code
0
A
P
2
2
End code
RFID System
106
Operation Manual
R/W Head No.
Read area start address
1 / 2
x
x
x
x
x
1
4
Always "H" (hexadecimal code).
Specifies the Read/Write Head with which to communicate.
1: Read from Read/Write Head 1 and write to Read/Write Head 2.
2: Read from Read/Write Head 2 and write to Read/Write Head 1.
Specifies the first address from which to read data from the Data Carrier as a four-digit hexadeci-
mal number.
Specifiable range: 0000H to FFFFH
Specifies the number of bytes of data to copy as a four-digit hexadecimal number.
Specifiable range: 0001H to 0800H
Specifies the first address to which to write data to the Data Carrier as a four-digit hexadecimal
number.
Specifiable range: 0000H to FFFFH
Terminator
0
*
CR
2
Indicates the results of command execution. An end code of 00 is returned for a normal end.
Refer to End Codes for more information.
p.135
Copy destination write
No. of bytes to copy
start address
x
x
x
x
x
x
4
4
Terminator
x
*
C R
2