Omron V600 Series User Manual page 115

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Check/End specification
Subcommands
R/W Head No.
Terminator
Command code
C/E
1/2
P
W
*
2
1
1
Check/End specification
R/W Head No.
Subcommand Responses
Command code
End code
Terminator
0
0
*
P
W
2
2
End code
CR
2
Specifies checking processing results or ending (terminating) the command.
C: Check processing
E: End
Specifies the Read/Write Head for querying or canceling.
1: Read/Write Head 1
2: Read/Write Head 2
CR
2
Indicates the results of command execution.
00: Normal end
74: A Data Carrier has not approached when the command to check results was executed.
75: A Data Carrier has not approached when polling auto processing was ended.
76: Communications with the Data Carrier were in process or processing was finished when poll-
ing auto processing was ended.
Refer to End Codes for more information.
p.135
Section 5
Communications
RFID System
113
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca5d02V600-ca5d01

Table of Contents