Omron V600 Series User Manual page 53

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Factory Settings
SW1
Controller Number Switch 1 (Upper digit: 0 to 9)
SW2
Controller Number Switch 2 (Lower digit: 0 to 9)
SW3 pin 1
DIP switch/internal setting selector
SW3 pin 2
Baud rate setting 1
SW3 pin 3
Baud rate setting 2
SW3 pin 4
Baud rate setting 3
SW3 pin 5
Data length setting
SW3 pin 6
Parity setting 1
SW3 pin 7
Parity setting 2
SW3 pin 8
Stop bit setting
SW3 pin 9
Communications protocol setting
SW3 pin 10
Reserved.
Priority mode switch
SW4 pin 1
SW4 pin 2
Verify setting
SW4 pin 3
Display switch
SW4 pin 4
Lower trigger execution
SW4 pin 5
Reserved.
SW4 pin 6
Test switch
SW4 pin 7
Reserved.
SW4 pin 8
TEST head specification
SW4 pin 9
TEST command specification
SW4 pin 10
Reserved.
SW5
Mode switch
Terminating resistance switch
SW6
Factory
Name
Preparing Communications
Description
setting
0
Controller number 00
0
OFF
DIP switches enabled
OFF
Baud rate: 2,400 bps
OFF
OFF
OFF
Data length: 7 bits
OFF
Parity: Even
OFF
OFF
Stop bits: 2 bits
OFF
1:1
OFF
Not used.
Communications distance
OFF
priority
OFF
Verification enabled
OFF
End code display
OFF
No lower trigger
OFF
Not used.
OFF
Test stopped
OFF
Not used.
OFF
Read/Write Head 1 designated
OFF
Read test
OFF
Not used.
OFF
RUN mode
Terminating resistance not
OFF
connected.
Section 3
More
information
p.52
p.53
p.54
p.55
RFID System
51
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca5d02V600-ca5d01

Table of Contents