Omron V600 Series User Manual page 129

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

■ 1:N Communications
Command
Controller No.
Command code
Process code
@
x
x
C
C
3
2
Process code
OUT1/OUT2 control
Response
End code
Command code
Controller No.
x
C
C
0
@
x
3
2
2
End code
Input status
Output status
OUT1
OUT2
control
control
FCS
Terminator
0
0
x
x
x
x
2
1
1
2
Always "00".
0: No operation
1: Turn ON output
2: Turn OFF output
Output status
Input status
FC S
0
x
x
x
x
x
2
2
2
Indicates the results of command execution.
00: Normal end
Refer to End Codes for more information.
p.135
The current input status. First character: IN1 or TRG1, Second character: IN2 or TRG2
0: OFF
1: ON
The output input status after execution. First character: OUT1, Second character: OUT2
0: OFF
1: ON
*
CR
2
Terminator
x
*
C R
2
Section 5
Communications
RFID System
127
Operation Manual