Installation and Wiring
■ Assembling and Connecting the Communications Connector
Use the communications connector provided with the ID Controller. The user must provide the con-
necting cable and the host computer connector. The ID Controller connector is manufactured by
OMRON and is protected from electromagnetic interference (EMI).
Controller end
OMRON
XM3B-0922-111
Socket
Connector Assembly
1.
Prepare the end of the cable.
40
5
Conductor lines
Shield braid
Shield tape
2.
Solder conductor lines and plug pins.
Plug
Crossover
3.
Set the hood housing A2 onto the plug, and secure the aluminum tape section with a clamp.
4.
Tighten the two connector holding screws, and then cover the assembly with housing B2 to complete
the connector.
RFID System
28
Operation Manual
OMRON
XM2S-0911
Hood
Note: Hood and Plug of the following are not attached.
OMRON
XM3A-0921
Plug
35
Cable bushing
10
12
Cable bushing
Aluminum tape
Lock screw (two
screws, M2.6)
Housing A2
Cable clamp
Host device end
Hood: XM2S-0911 equivalent
Plug: XM3A-0921 equivalent
• First pass the cable through the cable bushing.
• Unwind the shielded braid and turn the braid back over the cable
bushing. Turn approximately 10 mm of the shielded braid back
over the cable bushing.
• Wrap the lines with sealing tape.
Abbrevia-
Pin No.
tion
9
SG
2
SD
3
RD
4 (See note.)
RS
5 (See note.)
CS
Note Short pins 4 (RS) and 5 (CS) with a crossover
line inside the connector.
Housing B2
Signal name
Signal ground
Send data
Receive data
Request to send
Can send