Omron V600 Series User Manual page 117

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Subcommands
Controller No.
Command code
@
x
x
P
W
3
2
Check/End specification
R/W Head No.
Subcommand Responses
Controller No.
Command code
x
@
x
P
W
3
2
End code
Check/End specification
R/W Head No.
FCS
Terminator
C/E
1/2
*
CR
x
x
1
1
2
2
Specifies checking processing results or ending (terminating) the command.
C: Check processing
E: End
Specifies the Read/Write Head for querying or canceling.
1: Read/Write Head 1
2: Read/Write Head 2
End code
FCS
Terminator
0
0
x
x
*
CR
2
2
2
Indicates the results of command execution.
00: Normal end
74: A Data Carrier has not approached when the command to check results was executed.
75: A Data Carrier has not approached when polling auto processing was ended.
76: Communications with the Data Carrier were in process or processing was finished when poll-
ing auto processing was ended.
Refer to End Codes for more information.