Section 3
Preparing Communications
SW4 Pin 1: Priority Mode Switch
SW4 pin 1
OFF
ON
SW4 Pin 2: Verify Setting
SW4 pin 2
OFF
ON
SW4 Pin 3: Seven-segment Display Switch
SW4 pin 3
OFF
ON
SW4 Pin 4: Lower Trigger Execution Switch
SW4 pin 4
OFF
ON
SW4 Pins 5, 7, and 10: Reserved.
Do not change the settings of these pins. Leave them set to OFF.
SW4 Pin 6: Test Switch
SW4 pin 6
OFF
ON
Note: This switch is effective only in MAINTENANCE mode.
SW4 Pin 8: TEST Head Specification
SW4 pin 8
OFF
ON
Note: This switch is effective only in MAINTENANCE mode.
SW4 Pin 9: TEST Command Specification
SW4 pin 9
OFF
ON
Note: This switch is effective only in MAINTENANCE mode.
RFID System
54
Operation Manual
Communications Distance Priority Mode
Communications Time Priority Mode
Verification enabled.
Verification disabled.
End code display
I/O display
Disabled.
Enable (rising edge)
Test stopped.
Test executed.
Communicate with Read/Write Head 1.
Communicate with Read/Write Head 2.
Use read test.
Use write test.
Description
Description
Description
Description
Description
Description
Description