Omron V600 Series User Manual page 82

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Section 5
Communications
Command List
There are four major groups of commands.
■ Communications Commands
Communications Commands perform communications with Data Carriers.
Command code
RD
WT
XR
XW
ER
AR
AW
DF
AF
CP
AP
PR
PW
MDC/MDK
MDS/MDL
RP
■ General Communications Subcommands
These subcommands are used to cancel or abort command execution.
Command
code
AA
XZ
RFID System
80
Operation Manual
Name
READ
Reads Data Carrier memory.
WRITE
Writes Data Carrier memory.
EXPANSION READ
Reads up to 2 KB of Data Carrier memory data by dividing the data into frames.
EXPANSION WRITE
Writes up to 2 KB of Data Carrier memory data by dividing the data into frames.
EXPANDED READ
Reads up to 8 KB of Data Carrier memory data.
AUTO READ
Waits for a Data Carrier to approach and then reads Data Carrier memory.
AUTO WRITE
Waits for a Data Carrier to approach and then writes Data Carrier memory.
DATA FILL
Fills Data Carrier memory with the specified number of write bytes from the start
write address specified in the command.
AUTO DATA FILL
Waits for a Data Carrier to approach and then writes the specified number of
bytes of the specified data from the start write address specified in the command
to Data Carrier memory.
COPY
Writes data read from Data Carrier memory by one Read/Write Head to the
memory of a Data Carrier in the communications area of the other Read/Write
Head.
AUTO COPY
Waits until a Data Carrier approaches and then Writes data read from Data Car-
rier memory by one Read/Write Head to the memory of a Data Carrier in the
communications area of the other Read/Write Head.
POLLING AUTO READ
Waits for a Data Carrier to approach and then reads Data Carrier memory. Com-
mand processing results can be checked using a subcommand.
POLLING AUTO WRITE
Waits for a Data Carrier to approach and then writes Data Carrier memory. Com-
mand processing results can be checked using a subcommand.
MANAGEMENT DATA
Used to calculate and verify check codes in Data Carrier memory. Writes the cal-
CHECK and MANAGE-
culation result to Data Carrier memory.
MENT DATA CALCULATE
MANAGEMENT DATA
Used to manage the number of times memory in a Data Carrier without a battery
SUBTRACTION and
is overwritten.
MANAGEMENT DATA
LIMIT
WRITE REPEAT
Executes the most recently executed Write Command.
Name
COMMAND PROCESS-
Terminates communications with the Data Carrier.
ING TERMINATE
ABORT
Restores the initialization status of ID Controller, i.e., the status immediately after
power is turned ON. No response will be returned. Do not use the abort command
while communicating with a Data Carrier.
Description
Description
More informa-
tion
p.82
p.84
p.86
p.89
p.93
p.95
p.97
p.99
p.102
p.104
p.106
p.108
p.112
p.116
p.118
p.120
More informa-
tion
p.122
p.124

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V600-ca5d02V600-ca5d01