Section 3
Preparing Communications
Offline Tests in MAINTENANCE Mode
In MAINTENANCE mode, communications between the ID Controller and Data Carriers can be tested
without connecting to the host device.
Use offline testing to check installation positions before performing test operations.
Testing Host Device Communications
The TEST command can be used to test communications between the ID Controller and host device.
This enables checking cable connections and communications processing before testing the operation
of the entire system.
1.
Create a simple communications program on the host device to send the TEST command (TS).
If communications function properly, the ID Controller will send back the received data.
Test data: 262 characters max.
Refer to TEST Command (TS) for more information on the TEST command.
■ Example for 1:N Communications
The following command and response are for sending the test data "OMRON" to the ID Controller with
controller number 2.
Command
Controller No.
@
0
2
3
Response
Controller No.
@
0
2
3
RFID System
58
Operation Manual
Host Device Test Command
Host Device Response
Test data in response
p.125
Command code
Test data
O
M
R
O
T
S
2
5
Command code
Test data
O
M
R
O
T
S
2
5
A Command sent.
B Response received.
FCS
Terminator
N
1
4
*
CR
2
2
FCS
Terminator
N
1
4
*
CR
2
2