■ 1:N Communications
Command
Process
specifi-
Command code
Controller No.
cation
@
x
x
M
D
2
3
Process specification
R/W Head No.
Check block start address
No. of check block bytes
Response
Controller No.
Command code
End code
x
@
x
x
M
D
3
2
2
End code
Refer to Data Carrier Memory Check Function for details on memory checks.
p.68
R/W Head No.
No. of check
Check block start address
C/K
1/2
x
x
x
x
1
1
4
Specifies the check processing to perform.
C: Compare check code
K: Calculate check code
Specifies the Read/Write Head with which to communicate.
1: Read/Write Head 1
2: Read/Write Head 2
Specifies the first address of the check block as a four-digit hexadecimal number.
Specifiable range: 0000H to FFFDH
Specifies the number of bytes in the check block as a two-digit hexadecimal number.
Specifiable range: 00H and 03H to FFH (The maximum of 256 bytes will be read if 00H is speci-
fied.)
Specify two bytes more than the number of bytes in the area for which the check code is calcu-
lated.
Refer to Data Carrier Memory Check Function for details.
p.68
FCS
Terminator
x
x
x
*
CR
2
2
Indicates the results of command execution.
00: Normal end
75: Data normal (only when comparing check codes)
76: Data error warning (only when comparing check codes)
Refer to End Codes for more information.
p.135
block bytes
FCS
Terminator
x
x
x
x
*
CR
2
2
2