EXPANSION WRITE (XW)
For EXPANSION WRITE, the ID Controller writes up to 2 KB to Data Carrier memory data by dividing
the data into frames. If there is no Data Carrier in the communications area, an error response with an
error code of 72 (Data Carrier missing) will be returned.
The host device cannot send commands to the ID Controller until all response frames have been
returned. (Excluding the AA command and XZ command.)
■ 1:1 Communications
Command
Frame 1
Data
code
R/W Head No.
specifi-
Command code
Write area start address
cation
x
W
A/H
1/2
x
2
1
1
Frame 2 and Later Frames
Write data
x
x
x
x
x
n
Data code specification
R/W Head No.
Write area start address
Write data
Delimiter
Terminator
Response
Command code
End code
Terminator
x
W
0
0
*
CR
2
2
2
End code
Write data
x
x
x
x
x
x
4
n
Terminator
x
x
x
*
CR
1 or 2
Specifies the type of code in which the write data is being sent.
A: ASCII
H: Hexadecimal
Specifies the Read/Write Head with which to communicate.
1: Read/Write Head 1
2: Read/Write Head 2
Specifies the first address to which to write data to the Data Carrier as a four-digit hexadecimal
number.
Specifiable range: 0000H to FFFFH
The data to write to Data Carrier memory. Up to 2,048 bytes can be written with one command.
ASCII: 2,048 bytes (2,048 characters)
Hexadecimal: 2,048 bytes (4,096 characters)
CR: Indicates the end of the frame when there is another frame.
*CR: Indicates the end of the frame when there is not another frame.
Indicates the results of command execution. An end code of 00 is returned for a normal end.
Refer to End Codes for more information.
p.135
Terminator
x
*
CR
1 or 2
Section 5
Communications
RFID System
89
Operation Manual