Omron V600 Series User Manual page 142

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Section 6
Troubleshooting
System Errors
Error
code
Antenna power supply
92
voltage error
93
Memory error
RFID System
140
Operation Manual
Name
The voltage supplied to the Read/Write Head from the ID Controller has dropped.
• Prepare a replacement ID Controller.
A memory may have occurred in the ID Controller or noise may have caused an error.
• Reset the power supply.
• Turn ON the RESET input.
• Use the SP command to reset communications with the Data Carrier. (Prepare a
replacement if normal communications cannot be recovered.)
Description