Omron V600 Series User Manual page 122

Rfid system id controller
Hide thumbs Also See for V600 Series:
Table of Contents

Advertisement

Section 5
Communications
WRITE PROCESSING REPEAT (RP)
WRITE PROCESSING REPEAT executes the most recently executed Write Command.
■ 1:1 Communications
Command
Command code
Terminator
*
R
P
2
Response
Command code
End code
x
x
0
2
2
Command code
End code
Write Command information is cleared under the following condition.
If the ID Controller's power supply is reset
A command input error will occur if WRITE REPEAT is executed under this condition.
RFID System
120
Operation Manual
CR
2
Terminator
0
*
CR
2
The command code of the most recently executed Write Command.
Indicates the results of command execution.
00: Normal end
Refer to End Codes for more information.
p.135